EN

simple transition from ORCAVE 313-112 and 313-113 to CYKY cable

Orcave 313-LD-48/LIN CYKY

The adapter is used in installations where a classic 3-core CYKY cable is installed between the SMART-type luminaire and the control element. We do not recommend this solution for SMART lights, because due to the complexity of the assembly, it introduces the possibility of error (rotation of the voltage polarity, bad contact of the control wire, etc.) and is only indicated for cases of overhaul of older installations.

Orcave 313-LD-48/LIN CYKY

Features

Output Connector Parameters
Clamps
3, screw fixing with a flat groove
Vein cross-section
0.5 - 2.5mm2
Cable diameter
9 - 12mm
Cable type
typically CYKY, it is also possible to use a bran-coated face
Max current load
16A per terminal for 450V
Protection
IP67
Material
PA66
Length
170mm
Variants
Overview of valid combinations
for different types of cabling and lighting
Combination for SMART with CAT6
Source Adapter
313-LD-48/LIN CAT
Source-cable jumper
RJ45-RJ45
Connecting cable
CAT min class 6
Cable-lamp jumper
RJ45-RJ45
Output from luminaire
CAT6 terminated with RJ-45
Combination for SMART with CYKY 3x1.5
Transition from source
313-LD-48/LIN CYKY
Source-cable jumper
CYKY-3-CYKY / 12mm
Connecting cable
CYKY typically 3x 1.5mm2
Jumper cable-lamp
CYKY-3-CYKY / 12mm
Output from lamp
CYKY cable
Combination for ADVANCED with CYKY 5x1.5
Adapter from the source
no, the Orcave 303-111 LD source ends with a 5-core cable
Jumper source-cable
CYKY-5-CYKY / 14mm
Connecting cable
CYKY typically 5x 1.5mm2
Cable-lamp jumper
CYKY-5-CYKY / 14mm
Output from the lamp
CYKY 5-core cable

Orcave 313-LD-48/LIN CYKY

Design

The adapter is equipped with a 12-pin connector from the manufacturer for insertion into the control element Orcave 313-112 or 313-113. The short connecting cable is terminated in a 3-pin waterproof connector, into which the cable is correctly inserted, e.g. CYKY 3x1.5mm2.

Orcave 313-LD-48/LIN CYKY

Function

We do not recommend this switch for normal use. In the overview, we present it for the case when, either for conservatively traditional reasons, the installer wants to use a 3-core CYKY cable for SMART lights, or it is a case of refurbishing old lights in lighting locations where he does not want to remake the existing CYKY cabling.